Transformer oil furfural testing method with chromatography pump support
A transformer oil method targeted furfural as an aging indicator for transformer paper insulation, using the DL/T 984-2018 reference and chromatography pump support to build a practical industrial testing workflow.
Background
Requirement context
The China site explains that furfural in transformer oil is associated with paper insulation aging. This creates a useful industrial application page beyond food, pharmaceutical, and environmental testing.
Selection challenges
What needed confirmation
Connect the industrial sample matrix to a chromatography method rather than a general instrument inquiry.
Confirm pump performance, detector selection, column conditions, and sample preparation requirements.
Document the reference method and aging-indicator purpose for technical review.
Workflow architecture
From requirement to quotation
Instruments
High-pressure pump, HPLC system, detector, column, and workstation by final method selection.
Confirmation Layer
Transformer oil sample, furfural target, reference method, flow requirements, and documentation.
RFQ Review
Industrial chromatography RFQ for transformer oil aging-indicator testing.
Configuration path
Application stages
Flow delivery
LC-500Q high pressure infusion pump or HPLC pump module
Provide stable flow for transformer oil furfural method conditions.
Chromatography analysis
HPLC separation, detector, column, and workstation by final method
Measure furfural as an indicator related to transformer paper insulation aging.
Result
RFQ output and buyer value
Reference method
DL/T 984-2018 was listed as the reference.
Industrial buyers can start from a recognized power-industry method.
Application value
Furfural content is used to evaluate transformer paper insulation aging.
The case links chromatography equipment to a clear maintenance and risk-control purpose.
The case expands Tianzhao's application coverage into power equipment oil testing.
It gives LC pump and HPLC modules a method-based use case.
The RFQ should request sample matrix, method reference, pump requirements, detector, column, and documents.
Related products
Instruments referenced in this case

LC-500Q
LC-500Q High Pressure Infusion Pump
High-pressure chromatography solvent delivery pump designed for precision, stability, and efficient flow control in analytical chromatography systems.
Workflow fit
Liquid delivery -> Flow control -> Module connection -> Auxiliary method support
RFQ: Flow range and liquid type
RFQ: Standalone or system accessory use
HPLC solvent delivery / Analytical chromatography systems
Details

LC500 HPLC
LC500 High Performance Liquid Chromatograph
High performance liquid chromatography system for routine analytical separation, quality control, and laboratory method work.
Workflow fit
Sample injection -> Separation method -> Detector output -> Chromatogram review
RFQ: Target method or analytes
RFQ: Detector and pump configuration
Pharmaceutical quality control / Food and agricultural testing
Details

Ultimate C18 Series
C18 HPLC Column
Ultimate C18 HPLC column series for routine reversed-phase liquid chromatography methods requiring stable peak shape, high efficiency, and broad method compatibility.
Workflow fit
Sample injection -> Separation method -> Detector output -> Chromatogram review
RFQ: Target method or analytes
RFQ: Detector and pump configuration
Reversed-phase HPLC analysis / Food and pharmaceutical methods
Details